Pump Tank Design
 
Pump Tank
Specifications on pump tank used in conjunction with Norweco® 960-500 units and some 960-750 units.
Pump Tank Size: 890 Gallons
Pump: 1/2 hp, 20 gallons per minute 115 V
Pump Float Switches: 3 switch system
    1.  Pump Switch - Normal operation.  When fluid level reaches high enough to pick up float, the pump will turn on with the time set on the control center.  
    2.  Override Switch - When fluid level rises to this float and raises it up, the timer will be bypassed and the pump will come on automatically any time of day.
    3.  High Water Alarm Switch - When fluid level rises to this point and raises the float you receive get an audible alarm and a visual alarm. This informs the owner that there is a problem with the pump or some electrical component. During this situation please call Hurt's as soon as possible. NOTE: There is a 24 hour reserve capacity.